Unarmoured cables offer flexibility, cost-effectiveness, and ease of installation for applications that do not necessitate additional mechanical protection. They are widely used in residential, commercial, and light industrial settings where the risk of physical damage is minimal. However, it is essential to consider the installation environment and potential hazards when deciding whether unarmoured cables are the right choice for a particular project. By understanding their specifications and weighing the pros and cons, you can make an informed decision regarding the best cable solution for your electrical needs.
Unarmoured cables are versatile electrical cables designed for applications that don't require the additional protection of an armoured layer. They offer flexibility and ease of installation, making them suitable for a wide range of environments. In this article, we will explore the specifications of unarmoured cables and examine their pros and cons.
Sed ut perspiciatis unde omnis iste natus error sit voluptatem accusantium doloremque laudantium, totam rem aperiam, eaque ipsa quae ab illo inventore veritatis et quasi architecto beatae vitae dicta sunt explicabo.
Type of insulation | 105* Heat Resistant PVC | Flame retardant Low Smoke (FRLS) | Halogen Free Flame Retadant (HFFR) from 1.0 to 4.0 sq.mm. |
Typical applications | Wiring of panels foruse in high ambient temperatures. | Wiring in high density critical installations in public places and fire prone areas. | Wiring in high density critical installations in public places and fire prone areas and in vicinity of electronic systems. |
Applicable standards | IS694,BS6500,BS6004, IEC227,DinVDE- 0281-3 | IEC 332-1,BS4066-1,IEC-754-1, ASTMD-2843,Astmd-2863,BS7211,IEC 1034,BS 6425-1 | IEC3313,BS406613,IEC754-2,ASTMD-2843,ASTMD-2863,BS211,IEC 1034, BD 6425-1, DIN VDE 0282-9 |
Cross Section area sq.mm. |
Approx. AWG |
Overall Dia., mm., Max. |
Insulation Thickness, mm, Nom. |
Conductor Config. No. of wires/ max. dia. |
Conductor Resist., ohm/km At 20*CMAx |
Max Current rating, Amp. |
Approx.voltage drop per amp per meter,mV |
0.50 | 22 | 02.6 | 0.6 | 16/0.20 | 39.00 | 006 | 46.0 |
0.75 | 20 | 02.8 | 0.6 | 24/0.20 | 26.00 | 009 | 31.0 |
1.00 | 18 | 03.0 | 0.6 | 32/0.20 | 019.5 | 014 | 22.0 |
1.50 | 16 | 03.4 | 0.7 | 30/0.25 | 013.3 | 018 | 15.0 |
2.50 | 14 | 04.2 | 0.8 | 50/0.25 | 07.98 | 024 | 9.10 |
4.00 | 12 | 04.8 | 0.8 | 56/0.30 | 04.95 | 032 | 5.70 |
6.00 | 10 | 05.6 | 0.8 | 84/0.30 | 03.30 | 042 | 3.80 |
10.0 | 8 | 07.0 | 1.0 | 124/0.30 | 01.91 | 055 | 2.20 |
16.0 | 6 | 08.2 | 1.0 | 1269/0.40 or 226/0.30 |
01.21 | 075 | 1.40 |
25.0 | 4 | 10.0 | 1.2 | 196/0.40 | 0.780 | 100 | 0.89 |
35.0 | 2 | 11.5 | 1.2 | 276/0.40 | 0.554 | 125 | 0.64 |
50.0 | 1 | 13.0 | 1.4 | 396/0.40 | 0.386 | 165 | 0.45 |
70.0 | 2/0 | 15.0 | 1.4 | 360/0.50 | 0.272 | 140 | 0.32 |
95.0 | 3/0 | 17.5 | 1.6 | 475/0.50 | 0.206 | 300 | 0.24 |
12.0 | 4/0 | 19.5 | 1.6 | 608/0.50 | 0.161 | 325 | 0.19 |
Nomminal Cross Sectional
Aria of Conductor |
No.of Wires
&Diameter ofWires
|
Nominal
Thickness ofInsulation |
Overall
Diameter Max |
Conductor
Resistance Ohm/km (Max) |
Curreny Rating |
(Sg mm) | (mm) | in(mm) | in(mm) | at20*C | (Amps) |
1.0(1/18) | 1/1.14mm | 0.70mm | 3.20mm | 18.1r/km | 12 |
01.0(3/22) | 3/0.66mm | 2.70mm | 3.20mm | 18.1r/km | 12 |
01.5(3/20) | 3/0.80mm | 0.70mm | 3.40mm | 12.1r/km | 16 |
02.5(7/22) | 7/0.68mm | 0.80mm | 4.20mm | 7.41r/km | 22 |
04.0(7/20) | 7/0.86mm | 0.80mm | 4.80mm | 4.61r/km | 29 |
06.0(7/18) | 7/1.05mm | 0.80mm | 5.60mm | 3.08r/km | 37 |
16.0(7/16) | 7/1.71mm | 1.00mm | 8.20mm | 1.15r/km | 68 |
Conductor
Area
|
No. & Size Of Each Strand
|
Max DC Conductor resystance at 20*C | Unsheathed Cable | Sheathed Cable | # Current Carrying Capicity | |||||
Copper | Aluminium | Insulation Thickness
Nominal |
Overall
Diameter Approx |
Insulation
Thickness Nominal |
Sheath
Thickness Norminal |
Overall
Dimeter Approx |
copper
Conducteor |
Aluminium
Conductor |
||
sq.mm. | mm. | ohm/km | ohm/km | mm. | mm. | mm. | mm. | mm. | Amp. | Amp. |
1.000
1.500 2.500 |
1/1.12
1/1.38 1/1.78 |
018.10
012.10 007.41 |
—–
018.10 012.10 |
0.7
0.7 0.8 |
2.600
2.900 3.500 |
0.6
0.6 0.7 |
0.8
0.8 0.8 |
04.10
04.40 05.00 |
010
013 020 |
008
010 015 |
4.000
6.000 10.00 |
1/2.25
1/2.78 1/3.55 Al 7/1.55 Cu |
004.61
003.08 001.83 |
007.41
004.61 003.08 |
0.8
0.8 1.0 |
4.000
4.500 5.700 6.200 |
0.8
0.8 1.0 |
0.9 0.9 1.0 |
05.85
06.40 07.55 08.05 |
026
035 044 045 |
020
027 034 035 |
16.00
25.00 35.00 |
7/1.70
7/2.14 7/2.52 |
001.91
001.20 00.868 |
004.61
003.08 001.83 |
1.0
1.2 1.2 |
7.200
8.900 10.00 |
1.0
1.2 1.2 |
1.0
1.1 1.1 |
09.30
11.20 12.30 |
055
075 090 |
043
058 070 |
50.00
75.00 90.00 |
7/2.98Al
19/1.80Cu 19/2.16 19/2.52 |
00.387
002.68 00.193 |
00.641
00.443 00.320 |
1.4
1.4 1.6 |
12.00
12.00 13.80 16.00 |
1.4
1.4 |
1.2
1.2 |
14.50
14.50 |
120
120 150 175 |
092
092 116 135 |
120.0
150.0 185.0 |
37/2.03
37/2.24 37/2.52 |
00.153
00.124 0.0991 |
00.253
00.206 00.164 |
1.6
1.8 2.0 |
17.60
19.50 21.80 |
—– | —– | —— | 200
230 265 |
155
175 205 |
240.0
300.0 400.0 |
61/2.24
61/2.50 61/2.86 |
0.0754
0.0601 0.0470 |
00.153
00.100 0.0778 |
2.2
2.4 2.6 |
24.80
27.50 31.10 |
—– | —– | —— | 315
370 450 |
245
285 350 |
500.0
630.0 |
61/3.22
91/2.98 |
0.0366
0.0283 |
0.0605
0.0469 |
2.8
2.8 |
35.00
38.80 |
—— | —– | —— | 530
590 |
410
455 |
Conductor Area | No. & Size of Each Strand | Cond. Bunched Dia. | Max.DC Resistance at 20*C | Insulation Thickness Nominal | Cable Dia. App. | #Current Carrying Capacity |
Sq.mm. | mm. | mm. | Ohm/mm. | mm. | Amp. | Amp. |
00.500 | 0016/0.20 | 01.60 | 39.00 | 0.60 | 02.20 | 004 |
00.750 | 0024/0.20 | 02.08 | 26.00 | 0.60 | 02.50 | 007 |
01.000 | 0032/0.20 | 02.60 | 19.00 | 0.60 | 02.60 | 011 |
01.500 | 0048/0.20 | 03.20 | 13.00 | 0.60 | 02.90 | 014 |
02.500 | 0080/0.20 | 04.67 | 07.00 | 0.70 | 03.60 | 019 |
04.000 | 0056/0.30 | 05.90 | 04.95 | 0.80 | 04.30 | 026 |
06.000 | 085/0.300 | 07.36 | 03.30 | 0.80 | 05.00 | 031 |
010.00 | 0140/0.30 | 08.74 | 01.91 | 1.00 | 06.80 | 042 |
016.00 | 0126/0.30 | 10.60 | 01.21 | 1.00 | 08.00 | 057 |
025.00 | 0196/0.40 | 12.56 | 00.78 | 1.20 | 10.00 | 071 |
035.00 | 0276/0.40 | 14.54 | 08.74 | 1.20 | 11.40 | 091 |
050.00 | 0396/0.40 | 16.45 | 10.60 | 1.40 | 13.70 | 120 |
070.00 | 0440/0.45 | 18.45 | 12.56 | 1.40 | 15.60 | 161 |
095.00 | 0590/0.45 | 20.40 | 14.54 | 0.60 | 18.00 | 200 |
120.00 | 0750/0.45 | 23.30 | 16.45 | 0.60 | 20.00 | 225 |
150.00 | 0943/0.45 | 26.00 | 18.45 | 0.60 | 22.30 | 240 |
185.00 | 1150/0.45 | 30.10 | 20.40 | 0.60 | 24.60 | 300 |
240.00 | 1500/0.45 | 00.94 | 23.30 | 0.60 | 28.00 | 425 |
300.00 | 1875/0.45 | 01.13 | 26.00 | 0.60 | 31.00 | 475 |
400.00 | 2500/0.45 | 01.31 | 30.10 | 0.60 | 35.70 | 550 |